  Commitment to Quality  
ATEX - Standards and Harmonised Status

Bedford Opto Technology Ltd. are very much aware of the harmonisation and deharmonisation of the standards used in the design and manufacture of it's ATEX Opto-Isolators. We decided at a very early stage to include our designated Notified Body to ensure our Opto-Isolators fulfilled the requirements of the standards applicable to it's product.

In October 2007 we received Supplementary EC-Type Examination Certificates:-
    BAS01ATEX1278U/2 that relates to - OPI110 Series
                                                           OPI1264 Series
                                                           OPI1000L Series
    BAS01ATEX1285U/3 that relates to - OPI2000M / OPI2000MTH
These confirm the re-examination of our Opto-Isolators and their compliance in all respects with:-
    EN60079-0:2006                EN61241-0:2006
    EN60079-11:2007              EN61241-11:2006
    EN60079-26:2004

For more information on this issue please refer to :- http://www.baseefa.com/page166.asp


ATEX Certification  

ATEX - ATmospheres EXplosibles - Directive 94/9/EC

BOT hold a Quality Assurance Notification from Baseefa Ltd and manufacture ATEX certified product and EC-Type Examination Certificates for the 10KV Opto-Coupler ranges and it's High Speed Opto-Isolator.

BAS01ATEX1278U/3

OPI110 Series
OPI1264 Series
OPI1000L Series

BAS01ATEX1278U/3

BAS01ATEX1285U/3

OPI2000M
OPI2000MTH

BAS01ATEX1285U/3

Baseefa ATEX 1632

Quality Assurance
Notification

QAN


Legislative Marks and Markings

  • Ex = Distinctive European Community Mark
  • II = Indicates non-mining (Group II)
  • G = Indicates a product suitable for use in an explosive atmosphere comprising a mixture of gas, vapour or mist with air.
  • D = Indicates a product suitable for use in an explosive atmosphere comprising a mixture of flammable dust with air.

Informative Markings

  • EEx = 'Ex' is the internationally accepted symbol of explosion protection. The 'E' prefix indicates that European standards are used.
  • ia = Each explosion protection concept is given a different lower case letter signifying compliance with the relevant European or International standard.
  • IIC = For use with a small number of gasses which require very little spark energy to ignite them.


 

 